TRUSTXCARE — Sharma Electrical and Electronics Logo
TRUSTXCARE
Sharma Electrical and Electronics
Get Quote
प्रमाणित वर्कशॉप जॉब रिकॉर्ड

वास्तविक वर्कशॉप केस स्टडी एवं प्रमाणित इंजीनियरिंग प्रोजेक्ट्स

हमारी बसैठा, मुजफ्फरपुर वर्कशॉप एवं बिहार भर के क्लाइंट परिसरों में किए गए वास्तविक रिपेयर और प्रोजेक्ट्स का तकनीकी विवरण।

Workshop Authenticity & Verification Policy

0 Owner-Signed Case Studies Live • 6 Capability Templates

We never publish fabricated client names, fake completion dates, or unverified before/after claims. Verified client case studies appear only after proprietor job-card verification, written naming permission (NAMED_WITH_PERMISSION or ANONYMIZED_INDUSTRY_CLIENT), and real workshop photographs (isVerifiedAndApproved: true). Below are our standard Basaitha workshop capability & testing workflow templates.

Filter by District, Industry Vertical, or Service
Capability Template (Pending Job-Log Approval)
Muzaffarpur District
Flour Mills (Atta Chakki & Roller Mills)

Three-Phase Flour Mill (Atta Chakki) Induction Motor Copper Rewinding

आटा चक्की थ्री-फेज इंडक्शन मोटर कॉपर बाइंडिंग एवं ओवरहाल

Client Display Mode: Anonymized Commercial Flour Mill — Muzaffarpur Belt • Corridor: PNB Chowk, Basaitha / Saraiya Corridor, Muzaffarpur

Equipment Class

3-Phase Squirrel Cage Induction Motor (TEFC)

Standard Rating & Supply

7.5 HP – 15 HP Range (Workshop Standard) (415V AC, 50 Hz)

Typical Fault Pattern Diagnosed

Stator phase-to-phase insulation breakdown caused by sustained low-voltage supply drops and grain-dust accumulation around cooling fins.

Standard Workshop Execution Steps

  • Complete stator strip-down, slot cleaning, and core inspection
  • Full rewinding using electrolytic copper magnet wire matched to OEM gauge and turn count
  • Class-F/H Nomex slot liner insulation, double insulating varnish impregnation, and heat curing
  • Heavy-duty ball bearing replacement with high-temperature grease packing
Testing & Acceptance Protocol: Standard workshop acceptance check: winding phase balance, Megger insulation resistance check, and no-load running current verification prior to handover.
Three-phase motor stator copper coil rewinding and Class-H slot insulation at Basaitha workshop
Representative View — Pending Job Photo
PNB Chowk, Basaitha / Saraiya Corridor, Muzaffarpur
Representative workshop schematic — replace with verified job photo upon approval

Verification Note: Template awaiting owner job-card selection, exact HP/make confirmation, real completion date, and authentic workshop photographs.

Capability Template (Pending Job-Log Approval)
Muzaffarpur District
Agriculture, Farms & Irrigation

Agricultural & Commercial Borewell Submersible Pump Rewinding & Bearing Overhaul

बोरवेल समरसेबल पंप मोटर बाइंडिंग एवं थ्रस्ट बेयरिंग ओवरहाल

Client Display Mode: Anonymized Irrigation & Borewell Client — Tirhut Belt • Corridor: Saraiya / Motipur / Kamalpura Belt, Muzaffarpur

Equipment Class

Water-Filled Borewell Submersible Pump Motor

Standard Rating & Supply

3 HP – 7.5 HP Range (Workshop Standard) (220V / 415V AC, 50 Hz)

Typical Fault Pattern Diagnosed

Water ingress past worn mechanical/oil seals and thrust-bearing wear causing rotor drag, high amp draw, and burnt PVC-insulated submersible winding.

Standard Workshop Execution Steps

  • Submersible stator stripping and core de-scaling
  • Rewinding with waterproof poly-wrapped submersible copper winding wire
  • Carbon thrust bearing assembly inspection, bush replacement, and shaft straightness check
  • Impeller stage cleaning and starter panel capacitor/overload relay check
Testing & Acceptance Protocol: Standard workshop test-tank submersion continuity check, Megger insulation test, and rated current verification.
Stainless steel borewell submersible pump motor assembly during workshop overhaul
Representative View — Pending Job Photo
Saraiya / Motipur / Kamalpura Belt, Muzaffarpur
Representative submersible pump view — pending verified customer job photo

Verification Note: Template awaiting owner verification of specific borewell pump job record and photographs.

Capability Template (Pending Job-Log Approval)
Muzaffarpur District
Manufacturing & Industrial Units

Star-Delta Motor Starter & LT Control Panel Troubleshooting for Agro-Industrial Unit

स्टार-डेल्टा मोटर स्टार्टर एवं एलटी कंट्रोल पैनल रिपेयरिंग

Client Display Mode: Anonymized Industrial Processing Unit — Muzaffarpur • Corridor: Bela Industrial Area & Kanti Corridor, Muzaffarpur

Equipment Class

Automatic Star-Delta Starter & LT Feeder Control Panel

Standard Rating & Supply

Up to 25 HP Motor Feeder Control (Workshop & Site Scope) (415V 3-Phase AC, 50 Hz)

Typical Fault Pattern Diagnosed

Pitted magnetic contactor tips, erratic timer changeover between star and delta stages, and single-phasing risk during load switching.

Standard Workshop Execution Steps

  • Contactor coil testing, silver-alloy contact inspection, and worn contactor replacement
  • Star-delta changeover timer calibration and thermal overload relay setting verification
  • Busbar tightening, lug crimping, and color-coded control harness dressing
  • Single-phase preventer and voltmeter/ammeter indicator verification
Testing & Acceptance Protocol: Standard panel check: dry-sequence changeover timing test, phase-failure trip check, and thermal inspection under running load.
Star-delta industrial motor starter control panel with contactors and relays
Representative View — Pending Job Photo
Bela Industrial Area & Kanti Corridor, Muzaffarpur
Representative LT starter panel schematic — pending verified site photo

Verification Note: Template awaiting owner confirmation of panel job log, client permission, and on-site photos.

Capability Template (Pending Job-Log Approval)
Sitamarhi District
Rice Mills & Agro-Processing Plants

Rice Mill Drive & Paddy Cleaner Motor Bearing & Insulation Overhaul

राइस मिल ड्राइव मोटर बेयरिंग एवं इंसुलेशन ओवरहाल

Client Display Mode: Anonymized Rice Milling Facility — North Bihar • Corridor: Sitamarhi – Muzaffarpur Milling Corridor

Equipment Class

3-Phase Totally Enclosed Fan-Cooled (TEFC) Mill Drive Motor

Standard Rating & Supply

10 HP – 25 HP Range (415V AC, 50 Hz)

Typical Fault Pattern Diagnosed

Excessive vibration and rotor-to-stator rubbing risk caused by seized drive-end bearing housing and husk/dust clogging cooling air ducts.

Standard Workshop Execution Steps

  • Full motor dismantling, stator core cleaning, and varnish re-coating
  • Bearing seat inspection and precision replacement of DE/NDE heavy-duty bearings
  • Cooling fan cowl cleaning and terminal box gasket/stud replacement
  • Dynamic balance and no-load current verification at Basaitha workshop
Testing & Acceptance Protocol: Standard overhaul sign-off: smooth bearing acoustics, balanced 3-phase current draw, and verified insulation resistance.
Heavy three-phase induction motors serviced for grain and rice milling applications
Representative View — Pending Job Photo
Sitamarhi – Muzaffarpur Milling Corridor
Representative 3-phase motor overhaul view — pending verified job approval

Verification Note: Template awaiting verified rice mill job record, client consent status, and authentic photos.

Capability Template (Pending Job-Log Approval)
Samastipur District
Cold Storage & Refrigeration Plants

Cold Storage Condenser & Blower Motor Moisture-Resistant Rewinding

कोल्ड स्टोरेज ब्लोअर एवं कंडेनसर मोटर मॉइस्चर-रेसिस्टेंट बाइंडिंग

Client Display Mode: Anonymized Cold Storage Unit — Samastipur / Vaishali Corridor • Corridor: Samastipur – Dalsinghsarai Agro Belt

Equipment Class

3-Phase Condenser Fan & Evaporator Blower Motor

Standard Rating & Supply

5 HP – 15 HP Range (415V AC, 50 Hz)

Typical Fault Pattern Diagnosed

Condensation and continuous seasonal operation causing stator winding moisture tracking and premature insulation failure.

Standard Workshop Execution Steps

  • Stator rewind with Class-H thermal and moisture-resistant copper winding
  • Double varnish dip and thermal oven baking for humid cold-room duty
  • Sealed bearing installation and terminal block moisture sealing
Testing & Acceptance Protocol: Standard cold-duty check: high-voltage Megger reading verification and continuous test-bench run.
Electrolytic copper magnet wire spools and Class-H thermal slot insulation materials
Representative View — Pending Job Photo
Samastipur – Dalsinghsarai Agro Belt
Representative copper winding material view — pending verified job record

Verification Note: Template awaiting owner verification of actual cold-storage job sheet and photography.

Capability Template (Pending Job-Log Approval)
Muzaffarpur District
Commercial Buildings, Shops & Offices

Commercial Mainline Voltage Stabilizer & Copper Transformer Rebuilding

कमर्शियल मेनलाइन स्टेबलाइजर एवं कॉपर ट्रांसफार्मर रिपेयरिंग

Client Display Mode: Anonymized Commercial Clinic & Retail Establishment — Basaitha Belt • Corridor: Basaitha / Kamalpura / Muzaffarpur City

Equipment Class

Automatic Mainline Voltage Stabilizer (5 KVA – 10 KVA Class)

Standard Rating & Supply

5 KVA – 10 KVA (90V–290V Input / 220V Regulated Output)

Typical Fault Pattern Diagnosed

Welded step-up relay contacts and overheated transformer primary winding caused by prolonged rural grid voltage fluctuations.

Standard Workshop Execution Steps

  • Burnt transformer coil rewinding with pure copper magnet wire and fresh insulating paper
  • Multi-stage switching relay bank testing and replacement of pitted relays
  • High-cut and low-cut sensing PCB calibration across wide input voltage range
Testing & Acceptance Protocol: Standard bench verification: accurate step switching, clean high/low voltage cut-off protection, and steady output voltage reading.
Automatic mainline voltage stabilizer transformer and relay switching board
Representative View — Pending Job Photo
Basaitha / Kamalpura / Muzaffarpur City
Representative stabilizer bench view — pending verified job sheet approval

Verification Note: Template awaiting owner approval of a specific commercial stabilizer repair record and real photo.

हिंदी ग्राहक सहायता (Bihar Helpdesk)PNB चौक, बसैठा, मुजफ्फरपुर (843101)

वर्कशॉप कार्य प्रक्रिया एवं टेस्टिंग मानक (बसैठा, मुजफ्फरपुर)

हमारी वर्कशॉप में हर जले हुए मोटर या खराब स्टार्टर पैनल की पहले मल्टीमीटर और मेगर से जांच होती है। शुद्ध कॉपर वाइंडिंग, वार्निश बेकिंग और लोड टेस्टिंग के बाद ही उपकरण ग्राहक को दिया जाता है।

  • क्लास-F और क्लास-H इंसुलेशन के साथ शुद्ध कॉपर वाइंडिंग
  • बोरवेल सबमर्सिबल और आटा चक्की मोटर की सटीक टेस्टिंग
  • पूरी तरह प्रमाणित एवं पारदर्शी कार्य विवरण
Portfolio & Verification Policy

अक्सर पूछे जाने वाले सवाल

अभी कॉल करें
WhatsApp
रेट / एस्टीमेट लें