Class-F & Class-H Thermal Insulation ke Saath Pure Copper Coil Rewinding
Hum 0.5 HP se 50+ HP electric motors ki precision copper stator rewinding karte hain. Hum strictly pure electrolytic copper wire, Class-F/H Nomex/Mylar slot liners aur controlled oven varnish baking use karte hain, taaki Bihar ke voltage swings aur heat mein motor lambi service de.

Core Engineering Features & Guarantees
Equipment ki Aam Problems Jo Hum Solve Karte Hain
Step-by-Step Restoration Process
Systematic bench procedure executed at our PNB Chowk, Basaitha workshop.
Data Logging & Strip-Out
Purana wire gauge, turns per coil aur core dimensions note karna.
Core Cleaning & Slot Insulation
Jala hua taar nikaal kar slots saaf karna aur naya Nomex paper lagana.
Precision Coil Winding
Pure copper wire se coils bana kar slots mein safely insert karna.
Lacing & Varnishing
Fiberglass tape se bandhai karna, connections jodna aur varnish mein immerse karna.
Oven Baking & Megger Test
Oven mein bake karke 1000V Megger aur no-load ampere testing karna.
Handover & Safety Advice
Root cause explanation, capacitor/relay preventive advice aur transparent workshop bill ke saath handover.
Electric Motor Rewinding Service (100% Pure Copper) FAQs
Direct engineering answers regarding inspection, materials, testing, and turnaround.
TRUSTXCARE • Sharma Electrical and Electronics
Motor Repair ya Industrial Electrical Kaam Ke Liye Ready Hain?
Hamari Basaitha, Muzaffarpur workshop se contact karein. Transparent rate, turant technical salah aur Bihar-wide dependable service payein.